Code 230611: SI MM: Defect in a monitoring channel
Issue Description & Safety Warning
The Siemens SINUMERIK 840D CNC has triggered a critical SI MM: Defect in a monitoring channel alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Safety notice — qualified personnel only
- Electrical: drives and power supplies can hold lethal voltage after power-off (DC-link capacitors). Isolate, lock out, and verify zero energy with a meter before touching terminals.
- Motion / gravity: releasing brakes or resetting an axis can let it drop or move unexpectedly. Support vertical axes and keep clear of the working envelope.
This page is a reference summary, not a substitute for the OEM manual or your site’s LOTO procedure. FaultResolve accepts no liability for work carried out based on it. See our Terms.
Message value: %1 Drive object: All objects Reaction: A_INFEED: NONE (OFF1, OFF2) SERVO: NONE (OFF1, OFF2, OFF3) VECTOR: NONE (OFF1, OFF2, OFF3) Acknowledge: IMMEDIATELY (POWER ON) Cause: The drive-based "Safety Integrated" function in the Mo tor Module (MM) has detected a fault in the data cross-check between the Control Unit (CU) and MM and initiated a STOP F. As a result of this fault, after the parameterized transition has expired (p9858), fault F30600 is output (SI MM: STOP A initiated). Fault value (r0949, interpret decimal): 0: Stop request from the Control Unit. 1 to 999: Number of the cross-checked data that resulted in this fault. This number is also displayed in r9895. 1: SI monitoring clock cycle (r9780, r9880). 2: SI enable safety functions (p9601, p9801). Cros swise data comparison is only carried out for the supported bits. 3: SI SGE changeover tolerance time (p9650, p9850). 4: SI transition period STOP F to STOP A (p9658, p9858). 5: SI enable Safe Brake Control (p9602, p9802). 6: SI Motion enable, safety-relevant functions (p9501, internal value). 7: SI pulse suppression delay time for Safe Stop 1 (p9652, p9852). 8: SI PROFIsafe address (p9610, p9810). 1000: Watchdog timer has expired. Within a per iod corresponding to approximately 5 * p9850, too many switching operations have occurred at the sa fety-relevant inputs of the Control Unit, or STO (including subsequent responses) has been tr iggered too frequently via PROFIsafe/TM54F. 1001, 1002: Initialization erro r, change timer / check timer. 2000: Status of the STO selection on the Control Unit and Motor Module are different. 2001: Feedback signal for safe pulse suppression on the Control Unit and Motor Module are different. 2002: Status of the delay timer SS1 on the Control Unit and Motor Module are different. SINAMICS-Alarms Diagnostics Manual (DAsl), 03/2009 Remedy: Re fault value = 1 to 5 and 7 to 999: - check the cross-checked data that resulted in a STOP F. - carry out a POWER ON (power off/on) for all components. - upgrade the Motor Module software. - upgrade the Control Unit software. Re fault value = 6: - carry out a POWER ON (power off/on) for all components. - upgrade the Motor Module software. - upgrade the Control Unit software. Re fault value = 1000: - check the wiring of the safety-relevant inputs (SGE) on the Control Unit (contact problems). - PROFIsafe: rectify contact problems/faults on t he PROFIBUS master/PROFI NET controller. - check the wiring of the fail-safe i nputs on TM54F (contact problems). Re fault value = 1001, 1002: - carry out a POWER ON (power off/on) for all components. - upgrade the Motor Module software. - upgrade the Control Unit software. Re fault value = 2000, 2001, 2002: - check the tolerance time SGE changeover and if required, increase the value (p9650/p9850, p9652/p9852). - check the wiring of the safety-relevant inputs (SGE) (contact problems). - check the cause of STO selecti on in r9772. Active SMM functions (p9501=1) can also cause STO to be selected. - replace the Motor Module involved. Note: CU: Control Unit MM: Motor Module SGE: Safety-relevant input SI: Safety Integrated SS1: Safe Stop 1 (corresponds to Stop Category 1 acc. to EN60204) STO: Safe Torque Off / SH: Safe standstill SMM: see r9772
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Siemens SINUMERIK 840D CNC Alarms
Siemens controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 230611 on the SINUMERIK 840D CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Siemens's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 4014 Siemens SINUMERIK 840D CNC codes.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.