Code xF1: DC bus voltage error
Issue Description & Safety Warning
The Trane TVR Pro VRF (220V) has triggered a critical DC bus voltage error alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Safety notice — qualified personnel only
- Electrical: drives and power supplies can hold lethal voltage after power-off (DC-link capacitors). Isolate, lock out, and verify zero energy with a meter before touching terminals.
- Pressurised / hot systems: refrigerant, hydraulic and pneumatic circuits must be depressurised by a certified technician.
This page is a reference summary, not a substitute for the OEM manual or your site’s LOTO procedure. FaultResolve accepts no liability for work carried out based on it. See our Terms.
Manual restart required: No Display: Displayed on the unit with the error Note: 'x' is a placeholder for the compressor system — 1 = compressor system A, 2 = compressor system B (e.g. 1F1 / 2F1). Description: 1F1 indicates compressor A DC bus voltage error; 2F1 indicates compressor B DC bus voltage error. All units stop running. Error code is only displayed on the unit with the error. Trigger condition: DC bus voltage < 150V or DC bus voltage >500V continuously for 10 seconds. Recover condition: DC bus voltage goes back to normal. Reset method: Restart automatically. Possible causes: - Loosened wiring of the compressor inverter module. - Incorrect wiring of the reactor and DC bus wire. - Abnormal power supply. - Inverter module damaged.
Source: Trane 220V TVR Pro VRF Service Manual — Part 6 Diagnosis and Troubleshooting
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Trane TVR Pro VRF (220V) Alarms
Trane controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code xF1 on the TVR Pro VRF (220V) identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Trane's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 38 Trane TVR Pro VRF (220V) codes.
Need a searchable reference for more Trane TVR Pro VRF (220V) manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.