Código oL1: Motor Overload

Descripción del problema y advertencia de seguridad

El Yaskawa A1000 AC Drive ha desencadenado una alarma crítica Motor Overload. Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.

Pasos oficiales de solución de problemas

Code type: Fault Manual section: Yaskawa A1000 Troubleshooting Load is too heavy. Reduce the load. Note: After the value of U4-16 has decreased to one less than 100, reset oL1. The value of U4-16 must be less than 100 before oL1 can be reset. Cycle times are too short during acceleration and deceleration. Increase the acceleration and deceleration times (C1-01 through C1-08). A general purpose motor is driven below the rated speed with too high load. - Reduce the load. - Increase the speed. - If the motor is supposed to operate at low speeds, either increase the motor capacity or use a motor specifically designed to operate in the desired speed range. V/f characteristics (voltage and frequency) are not suitable Set the V/f pattern setting parameters (E1-04 to E1-10) to match the motor characteristics. The wrong motor rated current is set to E2-01. - Check the motor-rated current. - Enter the value written on the motor nameplate to parameter E2-01. Multiple motors are running off the same drive. Disable the motor protection function (L1-01 = 0) and install a thermal relay to each motor. The electrical thermal protection characteristics and motor overload characteristics do not match. - Check the motor characteristics. - Correct the type of motor protection that has been selected (L1-01). - Install an external thermal relay. The electrical thermal relay is operating at the wrong level. - Check the current rating listed on the motor nameplate. - Check the value set for the motor rated current (E2-01). Motor overheated by overexcitation operation. - Overexcitation increases the motor losses and the motor temperature. If applied too long, motor damage can occur. Prevent excessive overexcitation operation or apply proper cooling to the motor. - Reduce the excitation deceleration gain (n3-13). - Set L3-04 (Stall Prevention during Deceleration) to a value other than 4. - Set n3-23 (Overexcitation Operation Selection) to 0 (disabled). Speed Search related parameters are set incorrectly. - Check values set to Speed Search related parameters. - Adjust the Speed Search current and Speed Search deceleration times (b3-02 and b3-03 respectively). - After Auto-Tuning, enable Speed Estimation Speed Search (b3-24 = 1). Output current fluctuation due to power supply loss Check the power supply for phase loss.

Source: Yaskawa AC Drive A1000 High Performance Vector Control Drive Technical Manual (SIEP C710616 21H)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

Acerca de las alarmas de Yaskawa A1000 AC Drive

Los controladores industriales construidos por Yaskawa están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un A1000 AC Drive arroja un código de error como oL1, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.

Lista completa de alarmas: 280 Yaskawa A1000 AC Drive códigos.

Have a better solution?

Help the industrial community by sharing your repair experience for code oL1.

Manual conversion service

Need a searchable reference for more Yaskawa A1000 AC Drive manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Códigos relacionados de Yaskawa A1000 AC Drive