Code oPE03: Multi-Function Input Selection Error

Issue Description & Safety Warning

The Yaskawa A1000 AC Drive has triggered a critical Multi-Function Input Selection Error alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

Code type: Operator programming error Manual section: Yaskawa A1000 Troubleshooting - The same function is assigned to two multi-function inputs. - Excludes “Not used” and “External Fault.” - Ensure all multi-function inputs are assigned to different functions. - Re-enter the multi-function settings to ensure this does not occur. The Up command was set but the Down command was not, or vice versa (settings 10 vs. 11). Correctly set functions that need to be enabled in combination with other functions. The Up 2 command was set but the Down 2 command was not, or vice versa (settings 75 vs. 76). - Run/Stop command for a 2-wire sequence was set (H1-□□ = 42), but Forward/Reverse command (H1-□□ = 43) was not. - “Drive Enable” is set to multi-function input S1 or S2 (H1-01 = 6A or H1-02 = 6A). Correctly set functions that need to be enabled in combination with other functions. - Two of the following functions are set at the same time: - Up/Down Command (10 vs. 11) - Up 2/Down 2 Command (75 vs. 76) - Hold Accel/Decel Stop (A) - Analog Frequency Reference Sample/Hold (1E) - Offset Frequency 1, 2, 3 Calculations (44, 45, 46) - Check if contradictory settings have been assigned to the multi-function input terminals at the same time. - Correct setting errors. The Up/Down command (10, 11) is enabled at the same time as PID control (b5-01). Disable control PID (b5-01 = 0) or disable the Up/Down command. Settings for N.C. and N.O. input for the following functions were selected at the same time: - External Search Command 1 and External Search Command 2 (61 vs. 62) - Fast Stop N.O. and Fast Stop N.C. (15 vs. 17) - KEB for Momentary Power Loss and High Slip Braking (65, 66, 7A, 7B vs. 68) - Motor Switch Command and Accel/Decel Time 2 (16 vs. 1A) - KEB Command 1 and KEB Command 2 (65, 66 vs. 7A, 7B) - FWD Run Command (or REV) and FWD/REV Run Command (2-wire) (40, 41 vs. 42, 43) - External DB Command and Drive Enable (60 vs. 6A) - Motor Switch Command and Up 2/Down 2 Command (16 vs. 75, 76) Check for contradictory settings assigned to the multi-function input terminals at the same time. Correct setting errors. One of the following settings was entered while H1-□□ = 2 (External Reference 1/2): - b1-15 = 4 (Pulse Train Input) but the pulse train input selection is not set for the frequency reference (H6-01 > 0) - b1-15 or b1-16 set to 3 but no option card is connected - Although b1-15 = 1 (Analog Input) and H3-02 or H3-10 are set to 0 (Frequency Bias) Correct the settings for the multi-function input terminal parameters. H2-□□ = 38 (Drive Enabled) but H1-□□ is not set to 6A (Drive Enable). H1-□□ = 7E (Direction Detection) although H6-01 is not set to 3 (for V/f Control with PG using terminal RP as speed feedback input). H1-□□ = 16 is selected when using PG-RT3. Correct the setting. PG-RT3 is not available for the application with Motor 2 Selection.

Source: Yaskawa AC Drive A1000 High Performance Vector Control Drive Technical Manual (SIEP C710616 21H)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Yaskawa A1000 AC Drive Alarms

Yaskawa controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code oPE03 on the A1000 AC Drive identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Yaskawa's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 280 Yaskawa A1000 AC Drive codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code oPE03.

Manual conversion service

Need a searchable reference for more Yaskawa A1000 AC Drive manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Yaskawa A1000 AC Drive Codes