FaultResolve
返回搜索目录
Search this section

Search Yaskawa A1000 AC Drive

Search other Yaskawa A1000 AC Drive alarms without going back to the model list.

Search all database

代码 oPE08: Parameter Selection Error

问题描述与安全警告

Yaskawa A1000 AC Drive 触发了严重的 Parameter Selection Error 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。

官方故障排除步骤

Code type: Operator programming error Manual section: Yaskawa A1000 Troubleshooting Attempted to use a function that is not valid for the selected control mode. Check the motor control method and the functions available. In Open Loop Vector Control, n2-02 is greater than n2-03 Correct parameter settings so that n2-02 is less than n2-03. In Open Loop Vector Control, C4-02 is greater than C4-06 Correct parameter settings so that C4-02 is less than C4-06. In OLV/PM, parameters E5-02 to E5-07 are set to 0. - Set the correct motor code in accordance with the motor being used (E5-01). - When using a special-purpose motor, set E5-□□ in accordance with the test report provided. Both E5-09 and E5-24 are set to 0, or are not 0 in control modes for PM. Set E5-09 or E5-24 to the correct value, and set the other to “0”. In AOLV/PM High Frequency Injection is disabled (n8-57 = 0) and the minimum frequency (E1-09) is set lower than 1/20 of the base frequency setting. Correct the parameter settings. Or, set n8-57 to 1 to enable High Frequency Injection. Note: Use U1-18 to find which parameters are set outside the specified setting range. Other errors are given precedence over oPE08 when multiple errors occur at the same time.

Source: Yaskawa AC Drive A1000 High Performance Vector Control Drive Technical Manual (SIEP C710616 21H)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

关于 Yaskawa A1000 AC Drive 警报

由 Yaskawa 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 A1000 AC Drive 出现类似 oPE08 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。

完整报警清单: 280 Yaskawa A1000 AC Drive 代码s.

Have a better solution?

Help the industrial community by sharing your repair experience for code oPE08.

Manual conversion service

Need a searchable reference for more Yaskawa A1000 AC Drive manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

相关的 Yaskawa A1000 AC Drive 代码