代码 601109: Swivel head not clamped

问题描述与安全警告

Chiron Siemens-Control CNC 触发了严重的 Swivel head not clamped 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。

官方故障排除步骤

Function "Clamp swivel head clamping" was output, but the swivel head clamping is not yet clamped, or signals that it is still unclamped. PLC input signal "Swivel head clamping clamped" is not registered or "Swivel head clamping unclamped" is still registered. The error has the following effect: Feed Stop No axis movements possible. Read disable Control reads no further program blocks into memory. If the sensor signals are correct within a monitoring period, the program run is continued. After the monitoring time has elapsed, the machine stops. 1. Check PLC input signals "Swivel head clamping clamped". 2. Check PLC input signals "Swivel head clamping unclamped". 3. Check PLC input signals "Pressure sensors". 4. Check PLC output signals "Clamp swivel head clamping". 5. Check PLC output signals "Unclamp swivel head clamping". 6. Check PLC output signals "Valves". 7. As soon as the malfunction has been remedied, press [FEED START], [CYCLE START] or [RESET] key. Message is cleared.

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

关于 Chiron Siemens-Control CNC 警报

由 Chiron 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 Siemens-Control CNC 出现类似 601109 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。

完整报警清单: 545 Chiron Siemens-Control CNC 代码s.

Have a better solution?

Help the industrial community by sharing your repair experience for code 601109.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

相关的 Chiron Siemens-Control CNC 代码