代码 700746: Turning has not been deactivated --> Switch off main switch
问题描述与安全警告
Chiron Siemens-Control CNC 触发了严重的 Turning has not been deactivated --> Switch off main switch 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
The function "Turning“ was not correctly deactivated for some reason. The coordinate system is still turned. Error messages Swivel head Turning has not been deactivated --> Switch off main switch Feed Stop, since the coordinate system was not correctly switched. This is a serious error and can only be remedied with [Main switch OFF]. and [Main switch ON] If the error is still there, it must be checked whether ASUP_1_M is in the directory of the manufacturer cycles, and whether the _Reset cycle was called in this. When the control is started up, ASUP is run and the coordinate system is put in its original state.
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Chiron Siemens-Control CNC 警报
由 Chiron 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 Siemens-Control CNC 出现类似 700746 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 545 Chiron Siemens-Control CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700746.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026