代碼 700024: PLC-MD wrong (coolant)
問題描述與安全警告
Chiron Siemens-Control CNC 觸發了嚴重的 PLC-MD wrong (coolant) 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
An inconsistency has been found between the coolant version used for the machine and the corresponding PLC machine data. The error has the following effect: Feed Stop No axis movements possible. Read disable Control reads no further program blocks into memory. 1. Match the PLC machine data to the coolant unit in use. 2. Turn off the control with the key [Control OFF] 3. Turn on the control with the key [Control ON] Message is cleared. This is a collective message. Error messages Cooling lubrication PLC-MD wrong (coolant) In the PLC status DB181.DBB2718, it is indicated which component or which PLC machine parameter has caused this message to appear. The corresponding bit, then, has a (1). In the following table, these bits are shown in more detail. DB Description DB181.DBB2718Bit 0 The coolant system “without high pressure“ is selected, but one of the "coolant high pressure" functions M7/M171-M177 was output. DB181.DBB2718Bit 1 A coolant system was activated which has no paperband filter, but the PLC input signal "Paperband filter present" is registered. DB181.DBB2718Bit 2 The coolant system "Without high pressure" was activated, but the PLC input signal "Clean water minimum" or "Superclean water minimum" is registered. DB181.DBB2718Bit 3 The PLC machine parameter "Without moisture sensor main spindle motor" was set, but the PLC input signal "Moisture sensor main spindle motor" is registered. DB181.DBB2718Bit 4 The coolant system "Without high pressure" was activated, but the PLC input signal "Coolant filter" is registered. DB181.DBB2718Bit 5 A PLC machine parameter "Without flow control device xxx" was set, but the PLC input signal "flow control device xxx" is registered. DB181.DBB2718Bit 6 DB181.DBB2718Bit 7
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Chiron Siemens-Control CNC 警報
由 Chiron 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 Siemens-Control CNC 出現類似 700024 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 545 Chiron Siemens-Control CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700024.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026