Código 700055: Pm required

Descripción del problema y advertencia de seguridad

El Chiron Siemens-Control CNC ha desencadenado una alarma crítica Pm required. Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.

Pasos oficiales de solución de problemas

Warning limit of a maintenance cycle has been reached. Machine maintenance is required. In the diagnostics menu Maintenance cycles, it is shown what maintenance is required. The message is displayed immediately, but the machining program still continues until the program end. Renewed Acknowledgement or machine Start remain blocked. (Restricted operation is still possible. See note) Optional: The „red“ signal indication flashes (1HZ); The "white" signal indication continues to blink. (Cycle: ON = 0.4 sec / pause = 2 sec) These displays are retained until "Confirmation of maintenance" or "Maintenance delay". 1. In the diagnostics menu Maintenance cycles, check which maintenance is required. The "hours display" of the pending maintenance cycle is shown inverted. 2. The required maintenance should be carried out and confirmed now, as the machine can no longer be used after the production stop limit is reached. 3. The procedure for maintenance acknowledgement is explained in chapter: Confirm maintenance 4. After confirming the maintenance, press the following key: [FEED START] Message is cleared. In order not to significantly influence the current production, the operator has the option of acknowledging the message for another machining time of 2 hours. To do this, press the following key: [FEED START] The red signal indicator goes out again after acknowledgement. The operating message and white signal indicator remain active. This is possible until the maintenance cycle production stop limit is reached. It is now up to the operator to decide when he will carry out the maintenance (such as at the end of the shift). The menu can be found under: Chapter 2.7 ‘Maintenance cycles’ on page 12 Error messages Maintenance Pm required "Restricted" working with the machine can be reset by entering a password (maintenance delay) until the "production stop" limit is reached if the maintenance personnel is not yet able to carry out the required maintenance (due to lack of material, etc.). The machine comes to an ultimate standstill if the maintenance has not been carried out by this time.

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

Acerca de las alarmas de Chiron Siemens-Control CNC

Los controladores industriales construidos por Chiron están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un Siemens-Control CNC arroja un código de error como 700055, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.

Lista completa de alarmas: 545 Chiron Siemens-Control CNC códigos.

Have a better solution?

Help the industrial community by sharing your repair experience for code 700055.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Códigos relacionados de Chiron Siemens-Control CNC