Code 700229: X-axis collision! (Check reference point)

Issue Description & Safety Warning

The Chiron Siemens-Control CNC has triggered a critical X-axis collision! (Check reference point) alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

It has been determined that a collision has occurred on the machine. Note ! As a result of the collision, there is a danger that the axis reference points and the spindle positioning are no longer accurate. (Mechanical offset) The error message appears immediately. It should be determined on which axis a collision occurred (using the error message). Feed Stop in automatic and manual input modes. 1. Check the reference point and geometry of the axes. 2. Check the spindle concentricity and positioning. 3. Check the transfer positions of the tool changer. 4. The error message can be reset as follows on completing the check. 5. Switch to manual input mode. 6. Output M88. 7. Press [RESET] and [FEED START] at the same time. The axis on which a collision occurred is shown in the PLC status. There is then a (1) in the corresponding flag. M193.0 = X-axis M193.1 = Y-axis M193.2 = Z-axis For the purpose of adjustment or optimization of the axes this error message can be switched off by means of an M-function. This function is then effective until deselected or until the next RESET. M398 = error messages are not output or monitored. M399 = delete function M398. Miscellaneous Note ! No more indications regarding checking the reference point occur after this function is activated. There is no assurance that the reference point is still correct after a collision.

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Chiron Siemens-Control CNC Alarms

Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 700229 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 545 Chiron Siemens-Control CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 700229.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Chiron Siemens-Control CNC Codes