代码 700233: Fault data transmission for tool management
问题描述与安全警告
Chiron Siemens-Control CNC 触发了严重的 Fault data transmission for tool management 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
A serious fault has occurred on reading / writing the tool data. This fault occurs if a tool is cleared from the NC – tool corrections or is not present. Feed Stop Read-in enable missing. 1. Check with the NC – tool corrections whether all tools are present. All tools which are in the Chiron - Tool management should be present. (Set up afresh any missing tools) 2. Switch to manual mode. 3. Press [RESET] key. Message is cleared. A tool overview can be found in the menu Parameters Tool correction Overview If all tools are present and the error occurs frequently, inform the Service department. A serious fault has occurred on reading / writing the tool data. Cause 1: Cause 2: Error occurs as soon as T0 is in the spindle and one attempts, e.g.: to test for a broken tool (for example). Because „T0“ is in the spindle, attribute A of this tool place cannot be found and written over. Feed Stop Read-in enable missing. 1. Change the tool in the spindle (TxxM6). Test tool breakage with a tool in the spindle. 2. Switch to manual mode. 3. Press [RESET] key. Message is cleared. A tool overview can be found in the menu Parameters Tool correction Overview
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Chiron Siemens-Control CNC 警报
由 Chiron 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 Siemens-Control CNC 出现类似 700233 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 545 Chiron Siemens-Control CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700233.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026