Código 700352: Tool holder not correctly seated in tool magazine (1)
Descripción del problema y advertencia de seguridad
El Chiron Siemens-Control CNC ha desencadenado una alarma crítica Tool holder not correctly seated in tool magazine (1). Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.
Pasos oficiales de solución de problemas
A tool change is pending, but the check has indicated that there is a tool at the change place. This was previously incorrectly stored into the magazine. There is no corresponding bit "Tool place correctly occupied". 1 = Magazine place correctly occupied. 0 = Tool not present or not correctly inserted. As soon as there is a tool in the magazine, the corresponding bit "Magazine place correctly occupied" must be set in addition. The tool change is stopped and is not carried out further. Cause 1: 1. Tool change must be aborted. 2. Press [TOOL CH HOME POS.] key. Tool changer moves to home position. 3. Switch to NC operating mode "Manual mode". 4. Move magazine place to the loading position and check. 5. Remove the tool and store it in correctly. A tool was inserted in the loading position. Here, it was detected that a tool is present, but the "Tool correctly inserted (loading position)" switch does not signal. It is not possible to move the tool magazine. The indicator light "Enable tool loading" flashes. 1. Check whether the tool at the loading position is "correctly" in the tool magazine 2. Check whether the tool magazine is in the correct position. With the tool removed, the indicator light [Enable tool loading] is permanently illuminated as soon as the magazine is in its correct position. 3. Check the proximity switch "tool correctly inserted (loading position)" and the PLC input signal. 4. Check the proximity switch "Magazine place free (loading position)" and the PLC input signal. Possible combinations: Tool removed: Magazine place free = [ 1 ] + tool correctly inserted = [ 0 ] Tool inserted: Magazine place free = [ 0 ] + tool correctly inserted = [ 1 ] 5. Once the malfunction has been remedied, the movement command for the tool magazine is enabled again. Cause 2: Error messages Tool change Tool holder not correctly seated in tool magazine (1)
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Acerca de las alarmas de Chiron Siemens-Control CNC
Los controladores industriales construidos por Chiron están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un Siemens-Control CNC arroja un código de error como 700352, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.
Lista completa de alarmas: 545 Chiron Siemens-Control CNC códigos.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700352.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026