Code 700362: Flow monitor coolant high pressure (1)

Issue Description & Safety Warning

The Chiron Siemens-Control CNC has triggered a critical Flow monitor coolant high pressure (1) alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

The coolant (high pressure) was switched on, but after the monitoring delay time elapsed, the PLC input signal "Flow control device, coolant high pressure (1)" is still at signal state [0]. After switching on the coolant, the flow control device is monitored at signal state [1] after a short delay time. Read disable Feed Stop / Spindle Stop The 2nd coolant pump is switched off. 1. Check coolant flow. Possible causes: Patrol filter in pipe to the column is blocked Tool channel blocked Purolator filter blocked Shut-off cock closed Error messages Cooling lubrication Flow monitor coolant high pressure (1) 2. Check the PLC output signal and activation for the 2nd coolant pump and 2nd coolant valve. 3. Check the setting of the flow control device and the coolant flow. 4. Check the PLC input signal “flow control device, coolant high pressure (1)“. 5. Press the following key: [FEED START] Pump is reactivated. Keep pressing the key until the flow control device signals OK. 6. If it doesn't signal OK, when the key is released, the pump is switched off again. To set the flow control device, service function M88 can be programmed. Pump is now no longer switched off in the event of an error. The delay time variable for monitoring during switch-on is set to 5 seconds by default. Flow control device, coolant high pressure (1): DB181.DBD2500 in ms If there is no flow control device in the system, this monitoring function can be deactivated with a machine parameter. Without flow control device coolant high pressure: MD 14512[29] bit 1 = 0

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Chiron Siemens-Control CNC Alarms

Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 700362 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 545 Chiron Siemens-Control CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 700362.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Chiron Siemens-Control CNC Codes