Code 700709: Error coolant flow monitor high pressure (1))
Issue Description & Safety Warning
The Chiron Siemens-Control CNC has triggered a critical Error coolant flow monitor high pressure (1)) alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Safety notice — qualified personnel only
- Pressurised / hot systems: refrigerant, hydraulic and pneumatic circuits must be depressurised by a certified technician.
This page is a reference summary, not a substitute for the OEM manual or your site’s LOTO procedure. FaultResolve accepts no liability for work carried out based on it. See our Terms.
Coolant (high pressure) was switched off, but after the delay time for monitoring has elapsed, the PLC input signal "Flow control device coolant high pressure" still signals signal state (1). After switching off the coolant, the flow control device is monitored at signal state [0] after a short delay time. Monitoring takes place as soon as no Rapid feed (G00) is active. Feed Stop / Spindle Stop 1. Check the setting of the flow control device and the coolant flow. 2. Check the PLC input signal “flow control device, coolant high pressure (1)“. 3. As soon as the malfunction has been remedied, press [FEED START] or [CYCLE START]: Message is cleared. The delay time variable for monitoring during switch-off is set to 5 seconds by default. Flow control device, coolant high pressure (1): DB181.DBD2504 in ms Flow control device, coolant high pressure (2): DB181.DBD2516 in ms
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Chiron Siemens-Control CNC Alarms
Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 700709 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 545 Chiron Siemens-Control CNC codes.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.