コード 700746: Turning has not been deactivated --> Switch off main switch
問題の説明と安全警告
Chiron Siemens-Control CNC は重大な Turning has not been deactivated --> Switch off main switch アラームをトリガーしました。製造サイクル中に機器への二次的損傷や部品の破損を防ぐために、資格のあるオペレーターまたはメンテナンス技術者による直ちの対応が必要です。電気キャビネットにアクセスする前に、必ず標準の安全およびLOTO手順が遵守されていることを確認してください。
公式トラブルシューティング手順
The function "Turning“ was not correctly deactivated for some reason. The coordinate system is still turned. Error messages Swivel head Turning has not been deactivated --> Switch off main switch Feed Stop, since the coordinate system was not correctly switched. This is a serious error and can only be remedied with [Main switch OFF]. and [Main switch ON] If the error is still there, it must be checked whether ASUP_1_M is in the directory of the manufacturer cycles, and whether the _Reset cycle was called in this. When the control is started up, ASUP is run and the coordinate system is put in its original state.
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Chiron Siemens-Control CNC のアラームについて
Chiron によって構築された産業用コントローラーは、内部回路と機械的リンケージを保護するための広範な診断システムで設計されています。Siemens-Control CNC が 700746 のようなエラーコードをスローする場合、通常、指令値と実際のセンサーフィードバック間の不一致を示します。
完全アラーム一覧: 545 Chiron Siemens-Control CNC コードs.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700746.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.