代碼 700748: Error: Drive controller monitoring
問題描述與安全警告
Chiron Siemens-Control CNC 觸發了嚴重的 Error: Drive controller monitoring 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
The machine control was switched off, but the drive module still signalled OK. PLC input signal "Drive control monitoring function" signals a (0) signal. (No fault) The plausibility monitoring of the "Drive control monitoring“ signal occurs about 3 seconds after the machine control is switched off. As long as the PLC input signal "Drive control monitoring" signals (0), the machine control cannot be switched on. When the machine control is switched off, this must signal a (1). 1. As soon as the PLC input signal "Drive control monitoring function" signals a (1) again, switch on the machine control with the [Control ON] key. 2. Press [RESET] key. 3. Message is cleared. Error messages Drives Error: Drive controller monitoring Signal state "Drive control monitoring": 0 = machine control switched on 1 = machine control switched off
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Chiron Siemens-Control CNC 警報
由 Chiron 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 Siemens-Control CNC 出現類似 700748 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 545 Chiron Siemens-Control CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700748.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026