Code 701021: Error flow monitor exhaust fan (1)

Issue Description & Safety Warning

The Chiron Siemens-Control CNC has triggered a critical Error flow monitor exhaust fan (1) alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

The exhaust fan was switched off, but after the monitoring delay time elapsed, the PLC input signal "Flow control device, exhaust fan (1)/(2)" was still at signal state (1). After switching off the exhaust fan, the flow control device is monitored at signal state (0) after a short delay time. Monitoring takes place as soon as no Rapid feed (G00) is active. Feed STOP and Spindle STOP 1. Check the setting of the flow control device. 2. Check the PLC input signal "Flow control device, exhaust fan (1)/(2)“. 3. As soon as the malfunction has been remedied, press [FEED START] or [CYCLE START]: Message is cleared. The delay time variable for monitoring during switch-off is set to 5 seconds by default. Error messages Suction system Error flow monitor exhaust fan (1) Flow control device, exhaust fan (1): DB181.DBD2576 in ms Flow control device, exhaust fan (2): DB181.DBD2588 in ms

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Chiron Siemens-Control CNC Alarms

Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 701021 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 545 Chiron Siemens-Control CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 701021.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Chiron Siemens-Control CNC Codes