代碼 701422: Central lubrication system: interval not allowed ! PLC-MD wrong
問題描述與安全警告
Chiron Siemens-Control CNC 觸發了嚴重的 Central lubrication system: interval not allowed ! PLC-MD wrong 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
The option for central lubrication has been set, but no correct value for the interval time has been entered in the PLC machine parameter 14510[35]. Feed Stop 1. A correct value must be entered in the PLC machine parameter 14510[35]. Grease lubrication: An input from 1 up to 80 hours is permitted. Oil lubrication: An input from 10 up to 300 minutes is permitted. 2. “NCK-RESET“ is required after the machine parameter has been set. Grease lubrication: The standard setting is 8 or 25 hours. Oil lubrication: The standard setting is 240 or 300 minutes. Error messages Central lubrication system Central lubrication system: interval not allowed ! PLC-MD wrong
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Chiron Siemens-Control CNC 警報
由 Chiron 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 Siemens-Control CNC 出現類似 701422 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 545 Chiron Siemens-Control CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 701422.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.