代碼 701543: Safety device loader not closed
問題描述與安全警告
Chiron Siemens-Control CNC 觸發了嚴重的 Safety device loader not closed 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
The function "With loader" was activated, the machine is ready for loader mode, but the loader guard is not closed. PLC input signal "Loader guard closed“ is not present. The drives on the machine are switched off. It is impossible to operate the machine. 1. Check the guard of the loader and close it. 2. Check PLC input signal "Loader guard closed". 3. As soon as the malfunction has been remedied, press [FEED START] or [CYCLE START]: Message is cleared and the drives are activated again.
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Chiron Siemens-Control CNC 警報
由 Chiron 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 Siemens-Control CNC 出現類似 701543 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。