Code 701741: Time monitoring transport paper filter

Issue Description & Safety Warning

The Chiron Siemens-Control CNC has triggered a critical Time monitoring transport paper filter alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

The activation of the paper transport has exceeded a maximum running time of about 30 seconds. The PLC input signal “Transport paper filter“ stays on continuously. Evaluation and "Feed Stop" occur with non-automatic or with rapid feed (G0) or program end. The coolant (flush water) and the lifting pump are switched off immediately. Error messages Cooling lubrication Time monitoring transport paper filter 1. Check paper transport actuation. 2. Check the float switch and the PLC input signal. 3. As soon as the malfunction is remedied, press the following key: [FEED START] Message is cleared. By switching the machine control off and on again with [Control OFF] and [Control ON], the message is reset.

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Chiron Siemens-Control CNC Alarms

Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 701741 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 545 Chiron Siemens-Control CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 701741.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.