Code 701947: Tool gate not in tool gripper position

Issue Description & Safety Warning

The Chiron Siemens-Control CNC has triggered a critical Tool gate not in tool gripper position alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

It was attempted to load/unload a tool, but the tool gate is not in the position for transferring to the tool gripper. PLC input signal "Tool gate not closed (tool gripper position)" is registered. Loading/unloading is not started. [Start loading] key flashes quickly. Error messages Background magazine Tool gate not in tool gripper position 1. Check PLC input signal "Tool gate not closed (tool gripper position)". 2. To load/unload a tool, the tool gate must be in the tool gripper position, closed and locked. 3. Put the door of the tool gate in the position toward the tool gripper and continue the operation with the [Start loading] key. The diagnostic overview of the sensor signals can be found under: Chapter 2.2 ‘Tool changer diagnostics menu’ on page 11

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Chiron Siemens-Control CNC Alarms

Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 701947 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 545 Chiron Siemens-Control CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 701947.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Chiron Siemens-Control CNC Codes