Code 702253: Tool revolver tool change not executed
Issue Description & Safety Warning
The Chiron Siemens-Control CNC has triggered a critical Tool revolver tool change not executed alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
The command for a tool change has been output, but the change was not completed within a monitoring time of about 15 seconds. The error has the following effect: Feed Stop No axis movements possible. "Spindle Stop" Tool spindle is stopped. Speed no longer possible. 1. Please see the additionally pending error messages. 2. Once the malfunction has been remedied, press [RESET] key The message is cleared. If the centric clamp is in the machining position, the message applies to channel 1 and channel 3. If the centric clamp is not in the machining position, the message only applies to channel 3.
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Chiron Siemens-Control CNC Alarms
Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 702253 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 545 Chiron Siemens-Control CNC codes.
Have a better solution?
Help the industrial community by sharing your repair experience for code 702253.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026