Code 702711: Safety: EMERGENCY STOP safety relay monitoring
Issue Description & Safety Warning
The Chiron Siemens-Control CNC has triggered a critical Safety: EMERGENCY STOP safety relay monitoring alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
A The safety relay for "Emergency Stop OK" and "Control On" were switched off, but the feedback circuit "Monitoring Emergency Stop safety relay" is still missing. If the safety relays and contactors of the axis motors are deactivated, the feedback circuit must signal signal state [1] (check). B If the safety relays and contactors of the axis motors are activated, the feedback circuit must signal signal state [0] (check). Error messages Safety technology Safety: EMERGENCY STOP safety relay monitoring For A Not possible to switch on the machine control. For B Feed Stop and Spindle Stop are output in "AUTO" mode. It is not possible to unlock the protective door. After switching off the control, the protective door is unlocked after 10 seconds. 1. Check the feedback circuit and the PLC input signal "Monitoring Emergency Stop safety relay". (It could be that the relay is defective) 2. Exchange defective relay. 3. As soon as the malfunction is remedied, press the following key: [RESET] Message is cleared. 4. The machine control can be activated again. Feedback circuit monitoring takes 0.5 seconds.
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Chiron Siemens-Control CNC Alarms
Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 702711 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 545 Chiron Siemens-Control CNC codes.
Have a better solution?
Help the industrial community by sharing your repair experience for code 702711.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026