Code PS0114 / BG0114 / SR0114: ILLEGAL EXPRESSION FORMAT
Issue Description & Safety Warning
The Fanuc 0i-D / 0i Mate-D Alarm List has triggered a critical ILLEGAL EXPRESSION FORMAT alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Section: CNC alarm list Alarm group: Program/operation, background edit, communication (PS/BG/SR common alarm number) Original alarm number: 0114 The format used in an expression in a custom macro statement is in error. The parameter tape format is in error.
Source: Fanuc B-64305EN/03 Appendix A Alarm List
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Fanuc 0i-D / 0i Mate-D Alarm List Alarms
Fanuc controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code PS0114 / BG0114 / SR0114 on the 0i-D / 0i Mate-D Alarm List identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Fanuc's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 769 Fanuc 0i-D / 0i Mate-D Alarm List codes.
Have a better solution?
Help the industrial community by sharing your repair experience for code PS0114 / BG0114 / SR0114.
Need a searchable reference for more Fanuc 0i-D / 0i Mate-D Alarm List manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.