Code PS0127 / BG0127 / SR0127: DUPLICATE NC,MACRO STATEMENT
Issue Description & Safety Warning
The Fanuc 0i-D / 0i Mate-D Alarm List has triggered a critical DUPLICATE NC,MACRO STATEMENT alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Section: CNC alarm list Alarm group: Program/operation, background edit, communication (PS/BG/SR common alarm number) Original alarm number: 0127 An NC statement and macro statement were specified in the same block.
Source: Fanuc B-64305EN/03 Appendix A Alarm List
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Fanuc 0i-D / 0i Mate-D Alarm List Alarms
Fanuc controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code PS0127 / BG0127 / SR0127 on the 0i-D / 0i Mate-D Alarm List identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Fanuc's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 769 Fanuc 0i-D / 0i Mate-D Alarm List codes.
Have a better solution?
Help the industrial community by sharing your repair experience for code PS0127 / BG0127 / SR0127.
Need a searchable reference for more Fanuc 0i-D / 0i Mate-D Alarm List manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026