Code 5198: FSSB: ID DATA NOT READ
Issue Description & Safety Warning
The Fanuc 16i/18i/21i CNC has triggered a critical FSSB: ID DATA NOT READ alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Safety notice — qualified personnel only
- Electrical: drives and power supplies can hold lethal voltage after power-off (DC-link capacitors). Isolate, lock out, and verify zero energy with a meter before touching terminals.
This page is a reference summary, not a substitute for the OEM manual or your site’s LOTO procedure. FaultResolve accepts no liability for work carried out based on it. See our Terms.
The initial ID information for the amplifier cannot be read because of a failure in the temporary assignment.
Source: Fanuc Series 16i/18i/21i-B Operator's Manual, Appendix G Alarm List (B-63864EN/03)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Fanuc 16i/18i/21i CNC Alarms
Fanuc controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 5198 on the 16i/18i/21i CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Fanuc's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 360 Fanuc 16i/18i/21i CNC codes.
Need a searchable reference for more Fanuc 16i/18i/21i CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.