Code ER46: MESSAGE DATA UPDATE ERROR. PLEASE TRUN OFF POWER AFTER SAVING DATA.

Issue Description & Safety Warning

The Fanuc 30i/31i/32i CNC has triggered a critical MESSAGE DATA UPDATE ERROR. PLEASE TRUN OFF POWER AFTER SAVING DATA. alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

Save the corrected sequence program or message data for multi-language display to F-ROM. Moreover, turn the power off/on. The message data in the sequence program or the message data for multi-language display cannot be updated. It is necessary to turn off/on the power. The ladder program cannot be executed when this alarm occurs.

Source: Fanuc Series 30i/31i/32i-A Maintenance Manual, Appendix A Alarm List — PMC alarms (B-64485EN/01)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Fanuc 30i/31i/32i CNC Alarms

Fanuc controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code ER46 on the 30i/31i/32i CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Fanuc's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 85 Fanuc 30i/31i/32i CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code ER46.

Manual conversion service

Need a searchable reference for more Fanuc 30i/31i/32i CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Fanuc 30i/31i/32i CNC Codes