代码 ARC-057: Cannot ramp t1=%d > t2=%d
问题描述与安全警告
Fanuc R-30i Series Robot Controller 触发了严重的 Cannot ramp t1=%d > t2=%d 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Cause: Arc process ramping cannot continue because the delay to communicate between the robot and the welder (t1) is longer than the command update cycle time (t2). This may occur with weld schedule ramping or HeatWave Mode 2. Remedy: Normally, this appears just before ARC-133. If ARC-133 is also posted just after this alarm, there is no need to remedy. Please resume the program. If ARC-133 is not posted just after this alarm, please contact to your local FANUC representative.
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Fanuc R-30i Series Robot Controller 警报
由 Fanuc 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 R-30i Series Robot Controller 出现类似 ARC-057 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code ARC-057.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.