代码 INTP-292: more than 6 motion with DB executed
问题描述与安全警告
Fanuc R-30i Series Robot Controller 触发了严重的 more than 6 motion with DB executed 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Cause: More than six Distance Before (DB) motion options were processed at the same time. Remedy: Either change the termination type from CNT to FINE as in the example below, or reduce the number of DB motion options being used consecutively: 1: L P[1] 2000mm/sec CNT 100 DB 10mm DO[1] = ON 2: L P[2] 2000mm/sec CNT 100 DB 10mm DO[2] = ON 3: L P[3] 2000mm/sec CNT 100 DB 10mm DO[3] = ON 4: L P[4] 2000mm/sec CNT 100 DB 10mm DO[4] = ON 5: L P[5] 2000mm/sec CNT 100 DB 10mm DO[5] = ON 6: L P[6] 2000mm/sec FINE 7: L P[7] 2000mm/sec CNT 100 DB 10mm DO[7] = ON 8: L P[8] 2000mm/sec CNT 100 DB 10mm DO[8] = ON 9: L P[9] 2000mm/sec CNT 100 DB 10mm DO[9] = ON 10: L P[10] 2000mm/sec CNT 100 DB 10mm DO[10] = ON 11: L P[11] 2000mm/sec CNT 100 DB 10mm DO[11] = ON
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Fanuc R-30i Series Robot Controller 警报
由 Fanuc 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 R-30i Series Robot Controller 出现类似 INTP-292 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code INTP-292.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026