代码 SDTL-082: Register for payload center (%s) does not exist.
问题描述与安全警告
Fanuc R-30i Series Robot Controller 触发了严重的 Register for payload center (%s) does not exist. 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Cause: This alarm is displayed by execution of KAREL program, STPAYLOD. Register for payload center does not exist. %s shows coordinate (X or Y or Z) and index of the register. Suppose the 3rd argument of STPAYLOD is 200. Center of gravity of payload is specified by R [201]. If R[201] doesn’t exist, “SDTL-082 Register for payload center (X, 201) does not exist “ can be displayed. Remedy: Set proper value to the 3rd argument so that required registers exist. Suppose the 3rd argument of STPAYLOD is n. Center of gravity of payload is specified by following registers. R [n+1]: Position of center of gravity, X [cm] R [n+2]: Position of center of gravity, Y [cm] R [n+3]: Position of center of gravity, Z [cm]
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Fanuc R-30i Series Robot Controller 警报
由 Fanuc 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 R-30i Series Robot Controller 出现类似 SDTL-082 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code SDTL-082.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026