Code SRVO-023: Stop error excess(G:[number] A:[number])

Issue Description & Safety Warning

The Fanuc R-30i Series Robot Controller has triggered a critical Stop error excess(G:[number] A:[number]) alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

Safety notice — qualified personnel only

  • Electrical: drives and power supplies can hold lethal voltage after power-off (DC-link capacitors). Isolate, lock out, and verify zero energy with a meter before touching terminals.
  • Motion / gravity: releasing brakes or resetting an axis can let it drop or move unexpectedly. Support vertical axes and keep clear of the working envelope.

This page is a reference summary, not a substitute for the OEM manual or your site’s LOTO procedure. FaultResolve accepts no liability for work carried out based on it. See our Terms.

Root Cause: While holding a stationary posture, the axis positional following error exceeded the standstill limit ($PARAM_GROUP.$STOPERLIM), indicating the servo loop could not hold the commanded joint angle. Troubleshooting Steps: 1. Check whether the robot end-effector is physically wedged against a part, fixture, press platen, or conveyor stop pushing the arm off position while stopped. 2. Listen and watch the affected joint at the instant servos engage: if a gravity-loaded axis (commonly J2 or J3) sags slightly or groans, verify the holding brake actually releases when energized (check brake cable, brake fuse, and auxiliary axis brake-number mapping). 3. Verify payload schedule parameters (MENU > SYSTEM > MOTION) accurately reflect actual tool mass and center of gravity, and confirm incoming 3-phase line voltage is within +/-10% under load. 4. Inspect motor power connectors (U/V/W phases) for a backed-out crimp pin or swapped motor plugs after recent maintenance.

Source: FANUC Robot R-30iA Alarm Code List Operator's Manual

Last reviewed: 2026-11-27 · Verified against the manufacturer’s official documentation.

Expert Guidance

Field Experience, Common Misdiagnoses & Applicable Models

Source: FaultResolve Field Engineering Notes · Ref: FANUC B-83124EN / B-83284EN Series

Field Experience: On vertical load-bearing axes (J2 and J3 on R-2000iB/iC or M-710iC), SRVO-023 right after pressing deadman or cycle start is a textbook sign of either a stuck mechanical motor brake (trying to hold position or micro-adjust against a locked brake pad) or an open single motor phase (one U/V/W pin pushed back inside the Harting/Amphenol motor plug so the motor produces weak pulsating torque and sags under gravity the moment the brake releases). In CNC tending cells, SRVO-023 also triggers when a hydraulic chuck closes onto a part while the robot gripper is still rigidly clamping it without SoftFloat compliance active.

Common Misdiagnoses: Operators often re-teach the point slightly higher to "fix" SRVO-023 without noticing a failing motor brake coil or loose phase pin, leading to an uncontrolled gravity drop later. On 2-axis-brake legacy small robots or external positioners, misconfiguring the brake type/number software parameter causes instant SRVO-023 at standstill.

Applicable Models & Manual Editions: Covers all FANUC R-30iA, R-30iB, R-30iB Mate, and R-30iB Plus systems. Standstill threshold variable $PARAM_GROUP[g].$STOPERLIM is factory-tuned per mechanical model—never inflate it to mask hardware faults. Documented in B-83124EN-6/02 and B-83284EN/09.

About Fanuc R-30i Series Robot Controller Alarms

Fanuc controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code SRVO-023 on the R-30i Series Robot Controller identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Fanuc's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 6553 Fanuc R-30i Series Robot Controller codes.

Manual conversion service

Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.