Code SRVO-043: DCAL alarm(Group:[number] Axis:[number])
Issue Description & Safety Warning
The Fanuc R-30i Series Robot Controller has triggered a critical DCAL alarm(Group:[number] Axis:[number]) alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Safety notice — qualified personnel only
- Electrical: drives and power supplies can hold lethal voltage after power-off (DC-link capacitors). Isolate, lock out, and verify zero energy with a meter before touching terminals.
- Motion / gravity: releasing brakes or resetting an axis can let it drop or move unexpectedly. Support vertical axes and keep clear of the working envelope.
This page is a reference summary, not a substitute for the OEM manual or your site’s LOTO procedure. FaultResolve accepts no liability for work carried out based on it. See our Terms.
Root Cause: Regenerative braking energy returned to the servo amplifier DC bus exceeded the thermal dissipation capacity of the regenerative discharge resistor circuit (DCAL trip). Troubleshooting Steps: 1. Allow the regenerative resistor assembly to cool for several minutes, verify cooling airflow across the rear exterior resistor fin bank, and press RESET. 2. Review recent cycle-time optimizations: rapid consecutive vertical-downward decelerations (J2/J3) or high-inertia J1 swings dump kinetic energy back into the DC bus faster than the resistor duty cycle allows; reduce `ACC` overrides or insert brief dwell/blended `CNT` transitions. 3. Measure incoming 3-phase AC supply voltage—excessively high line voltage (near or above the +10% tap limit) raises baseline DC link voltage so the regenerative chopper fires prematurely on every deceleration. 4. Power down, wait 15 minutes for HVDC capacitor discharge, verify < 10 VDC on the bus, and ohm-check the regenerative discharge resistor, thermal cutout switch, and amplifier regen transistor.
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-11-27 · Verified against the manufacturer’s official documentation.
Field Experience, Common Misdiagnoses & Applicable Models
Source: FaultResolve Field Engineering Notes · Ref: FANUC B-83124EN / B-83284EN Series
Field Experience: On R-30iA and R-30iB cabinets, the regenerative resistor assembly sits in the external air plenum on the back of the cabinet with a bimetallic thermal thermostat wired in series back to the servo amplifier (CRRA12 / CXA20). Two field failures mimic genuine overload: (1) the rear external plenum blower seizes, so even light cycles overheat the regen resistor and open its thermal cutout; or (2) plant 480 V-to-230 V transformer taps are set one tap too high (delivering 248 VAC instead of 220–230 VAC), keeping the DC link right below the chopper threshold so the regen transistor conducts almost continuously.
Common Misdiagnoses: Engineers sometimes slow down a profitable production cell by 20% assuming the robot is overworked, without checking whether the external rear cooling fan behind the cabinet has stopped spinning or whether the step-down transformer primary tap needs adjusting for high plant line voltage.
Applicable Models & Manual Editions: Applies to FANUC R-30iA, R-30iB, R-30iB Mate, and R-30iB Plus controllers (note R-30iB Mate compact cabinets use smaller internal bleeder resistors and may require an optional external regen kit for high-duty cycles). Documented in B-83124EN-6/02, B-83284EN/09, and Maintenance Manual B-83195EN.
About Fanuc R-30i Series Robot Controller Alarms
Fanuc controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code SRVO-043 on the R-30i Series Robot Controller identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Fanuc's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 6553 Fanuc R-30i Series Robot Controller codes.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.