Code SRVO-075: Pulse not established(G:[number] A:[number])
Issue Description & Safety Warning
The Fanuc R-30i Series Robot Controller has triggered a critical Pulse not established(G:[number] A:[number]) alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Safety notice — qualified personnel only
- Motion / gravity: releasing brakes or resetting an axis can let it drop or move unexpectedly. Support vertical axes and keep clear of the working envelope.
This page is a reference summary, not a substitute for the OEM manual or your site’s LOTO procedure. FaultResolve accepts no liability for work carried out based on it. See our Terms.
Root Cause: Following a pulse coder reset (after SRVO-062 BZAL, battery loss, or encoder replacement), the pulse coder has not yet rotated past its internal single-turn reference index mark to establish absolute commutation/position counting. Troubleshooting Steps: 1. Ensure any upstream SRVO-062 (BZAL) has already been cleared via `RES_PCA` and a full controller power cycle—SRVO-075 will not clear while BZAL remains active. 2. Switch to T1 mode, turn the teach pendant ON, press COORD until `JOINT` jogging mode is selected (linear `WORLD`/`TOOL` jogging is unavailable before pulse establishment). 3. Hold the deadman switch at center, press RESET, and jog each axis listed in the SRVO-075 message approximately 10–20 degrees (at least one full motor shaft revolution) in either safe direction, pressing RESET whenever SRVO-075 re-triggers mid-jog until it stops appearing. 4. Once SRVO-075 clears on all affected joints, proceed to `MENU > SYSTEM > Master/Cal` to execute Mastering and `CALIBRATE`.
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-11-27 · Verified against the manufacturer’s official documentation.
Field Experience, Common Misdiagnoses & Applicable Models
Source: FaultResolve Field Engineering Notes · Ref: FANUC B-83124EN / B-83284EN Series
Field Experience: Every technician recovering a robot from dead batteries hits SRVO-075 and often thinks something is still broken when pressing RESET doesn't make it stay gone! Because high-ratio RV and harmonic reducers sit between the servo motor and the robot joint (ratios of 80:1 to 180:1), one full revolution of the motor shaft only moves the visible robot arm by ~2 to 4.5 degrees! However, while SRVO-075 is unestablished, the controller frequently halts jogging after a couple degrees and reposts SRVO-075—simply keep holding deadman, tap RESET, and jog another few degrees in JOINT mode two or three times until the encoder crosses its internal index pulse and the alarm vanishes permanently.
Common Misdiagnoses: Trying to jog in WORLD or USER coordinate frames while SRVO-075 is active (kinematics cannot compute Cartesian moves yet, throwing additional MCTL/INTP errors), or trying to run Zero Position Master / Quick Master before clearing SRVO-075—mastering buttons will fail until every axis has established its pulse!
Applicable Models & Manual Editions: Universal across FANUC R-30iA, R-30iA Mate, R-30iB, R-30iB Mate, and R-30iB Plus controllers. Documented in Alarm Code List B-83124EN-6/02 and B-83284EN/09.
About Fanuc R-30i Series Robot Controller Alarms
Fanuc controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code SRVO-075 on the R-30i Series Robot Controller identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Fanuc's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.