代码 SVGN-165: Gun opened < equalizer trigger distance.
问题描述与安全警告
Fanuc R-30i Series Robot Controller 触发了严重的 Gun opened < equalizer trigger distance. 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Cause: The open distance condition for equalization pressure trigger, was not met before the start of motion to pressure position, for the next spot. The equalization trigger state for the next spot might have been delayed, in this case. Remedy: Increase the end and/or start distance value on the distance schedule screen, or decrease the open distance for the equalization pressure trigger AFTER the SPOT.
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Fanuc R-30i Series Robot Controller 警报
由 Fanuc 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 R-30i Series Robot Controller 出现类似 SVGN-165 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code SVGN-165.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.