Code SVGN-273: Det was irregular stop. R:%d, P:%d

Issue Description & Safety Warning

The Fanuc R-30i Series Robot Controller has triggered a critical Det was irregular stop. R:%d, P:%d alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

Cause: A gun tip was contacted an upper panel surface on a free running section before search motion. Remedy: R:1 means that error occurred during upper panel detection. Confirm that gun tip has enough clearance from upper panel surface at start position. If distance between the tip and the panel is too short, confirm that: 1. no obstruction exists between guntip and panel. If the above item is OK, confirm that: 1. nominal thickness in pressure schedule is correct. 2. OverThickness tolerance (on gun teach setup screen) is large enough. If the above items are OK, confirm that: 1. Max allowable Pos error (on gun teach setup screen) is large enough. If the above item is NG, the position error is made less than maximum allowable position error in the following ways. 1. Touch up correct position using jog or point touchup(not program touchup). 2. Increase maximum allowable position error on gun teach setup screen. R:3 means that error occurred during lower panel detection. Confirm that robot tip has enough clearance from panel surface at start position and that there is no obstacle between the panel and the robot tip at start position. If distance between the tip and the panel is too short, increase start distance(SD) for robot tip and/or lower panel detection distance. Refer to Chapter “20.6 LOWER PANEL DETECTION DISTANCE CLAMP” or “20.13 SPTCH_RSD INSTRUCTION” in operator’s manual for Servo Gun Function for more information about the lower panel detection distance. Retry spot program touchup. If this problem persists after taking the above actions, perform the following actions: 1. Acquire the diagnostic data. See the procedure for diagnostic data collection at Chapter “20.19 Troubleshooting” in operator’s manual for Servo Gun Function.. 2. Contact your local FANUC representative. Note: This alarm is posted when the time to execute phases2,3 take longer than anticipated, during upper1 detection and lower detection. R: Request number. R:1 is upper1 detection. R:3 is lower detection. P: Phase number. P:2 is phase of acceleration. P3: is phase to collect data to calculate threshold. If the tip touch panel during above phase, this alarm is posted. Please check whether the tip touch panel or the gun is closed(or grabbed panel) at position of search start.

Source: FANUC Robot R-30iA Alarm Code List Operator's Manual

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Fanuc R-30i Series Robot Controller Alarms

Fanuc controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code SVGN-273 on the R-30i Series Robot Controller identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Fanuc's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 6553 Fanuc R-30i Series Robot Controller codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code SVGN-273.

Manual conversion service

Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Fanuc R-30i Series Robot Controller Codes