代码 SVGN-274: Too low speed threshold.
问题描述与安全警告
Fanuc R-30i Series Robot Controller 触发了严重的 Too low speed threshold. 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Cause: Threshold to detect panel contact became unexpectedly-low. Remedy: If gun tip contacted panel surface at start position, confirm that no obstruction exists between guntip and panel. If obstruction exists, remove it and retry spot program touchup or avoid it and touch up correct position using jog or point touchup(not program touchup). If robot tip contacted lower panel surface at start position, increase start distance(SD) for robot tip and/or lower panel detection distance. Refer to Chapter “20.6 LOWER PANEL DETECTION DISTANCE CLAMP” or “20.13 SPTCH_RSD INSTRUCTION” in operator’s manual for Servo Gun Function for more information about the lower panel detection distance. Retry spot program touchup. If this problem persists after taking the above actions, perform the following actions: 1. Acquire the diagnostic data. See the procedure for diagnostic data collection at Chapter “20.19 Troubleshooting” in operator’s manual for Servo Gun Function.. 2. Contact your local FANUC representative.
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Fanuc R-30i Series Robot Controller 警报
由 Fanuc 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 R-30i Series Robot Controller 出现类似 SVGN-274 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code SVGN-274.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.