Code 231-E01D: CC%2 SKERN Start requirement not fulfilled Id=%4, V=

Issue Description & Safety Warning

The Heidenhain TNC Series CNC has triggered a critical CC%2 SKERN Start requirement not fulfilled Id=%4, V= alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

%4 [Cause of error] - The requirements for starting cyclic operation are not fulfilled. [Error correction] - ID=1: Configuration was not successful. Check the additional information of the error messages E01A or E019. - ID=2: Check whether an error message E01E occurred. - ID=3: Your hardware version does not fulfill the requirements for safe operation. - Inform your service agency

Source: HEIDENHAIN NC Error Messages — TNC7/640/620/320/128, CNC PILOT 640, MANUALplus 620 (10/2023)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Heidenhain TNC Series CNC Alarms

Heidenhain controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 231-E01D on the TNC Series CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Heidenhain's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 4497 Heidenhain TNC Series CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 231-E01D.

Manual conversion service

Need a searchable reference for more Heidenhain TNC Series CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Heidenhain TNC Series CNC Codes