Code 238-101A: UVR%2 synchronization with line power supply failed
Issue Description & Safety Warning
The Heidenhain TNC Series CNC has triggered a critical UVR%2 synchronization with line power supply failed alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
[Cause of error] The synchronization between the supply unit and the supply network was not successful. [Error correction] - Check for a faulty connection of the main supply conductors - Check SITOR fuses for the inverter system - Check the power supply network - Inform your service agency
Source: HEIDENHAIN NC Error Messages — TNC7/640/620/320/128, CNC PILOT 640, MANUALplus 620 (10/2023)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Heidenhain TNC Series CNC Alarms
Heidenhain controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 238-101A on the TNC Series CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Heidenhain's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 4497 Heidenhain TNC Series CNC codes.
Have a better solution?
Help the industrial community by sharing your repair experience for code 238-101A.
Need a searchable reference for more Heidenhain TNC Series CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026