Code 293-001A: Invalid number programmed for FN17/18 No%1

Issue Description & Safety Warning

The Heidenhain TNC Series CNC has triggered a critical Invalid number programmed for FN17/18 No%1 alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

[Cause of error] - Incorrect number of FN17/18 programmed during access to look-ahead parameters. - The is no look-ahead parameter under this number. [Error correction] - Correct the corresponding FN17 or FN18 command.

Source: HEIDENHAIN NC Error Messages — TNC7/640/620/320/128, CNC PILOT 640, MANUALplus 620 (10/2023)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Heidenhain TNC Series CNC Alarms

Heidenhain controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 293-001A on the TNC Series CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Heidenhain's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 4497 Heidenhain TNC Series CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 293-001A.

Manual conversion service

Need a searchable reference for more Heidenhain TNC Series CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Heidenhain TNC Series CNC Codes