コード M01-1105: Spindle speed fluctuation

問題の説明と安全警告

Mitsubishi M800/M80 CNC は重大な Spindle speed fluctuation アラームをトリガーしました。製造サイクル中に機器への二次的損傷や部品の破損を防ぐために、資格のあるオペレーターまたはメンテナンス技術者による直ちの対応が必要です。電気キャビネットにアクセスする前に、必ず標準の安全およびLOTO手順が遵守されていることを確認してください。

公式トラブルシューティング手順

Details The actual spindle speed has fluctuated exceeding the allowable range, while spindle speed fluctuation detec- tion (G162) is active. The number following "S", which is output together with this alarm, indicates the spindle where speed fluctua- tions were detected. Remedy  Unnecessarily large load may be applied to the spindle during automatic operation. Reduce the spindle load.  To prevent this alarm from being output during sp indle speed fluctuation detec tion (G162), set the param- eter #1242 set14 BIT2 to ON. Sp synchro phase calc illegal 1106 Details Spindle synchronization phase alignment command was issued while the "phase shift calculation request" sig- nal was ON. Remedy  Correct the program.  Correct the sequence program. Illegal cmd in SP oscillation 1108 Details A function that cannot be used with spindle osc illation was commanded during spindle oscillation. Remedy  Command the function after finishing spindle oscillation. SP oscillation cmd illegal 1109 Details Spindle oscillation was commanded during executing a f unction that cannot be used with spindle oscillation. Remedy  Command spindle oscillation after finishing the func tion that cannot used with spindle oscillation. SP oscillation set val illegal 1110 Details Spindle oscillation was commanded while a value out of rang e is set as spindle oscillation amplitude or spindle oscillation frequency. Remedy  Check the setting values of the amplitude and frequency. Sub part system I call error 1111 Details  Sub part system control I command (G122) has been given to a part system where the sub part system I operation mode is deactivated.  Sub part system control I command (G 122) has been given to a part system which is not reserved as the sub part system in M80. Remedy  Activate the sub part system I operation mode for the sub part system before issuing G122. Part systems marked "SUB" on the monitor screen are under the sub partsys tem I operation mode.  Command the sub part system start to the sub part system which is reserved with "#1483 SBS1_sys num" for M80. Sub part system II start error 1112 Details When the sub part system control II has been commanded, no part system is left capable of being activated as a sub part system. Remedy  Do not exceed the maximum number of simultane ously activatable sub part systems when commanding G144.  Set the parameter #1437 SBS2_Spec BI T0 to 0 if you wish to wait unt il the sub part system becomes ca- pable of being activated. Constant surface speed rdndnt 1113 Details  Constant surface speed is commanded from other part syst em to the spindle that is in the thread/ thread cycle or the tapping cycle/ synchronous tapping cycle.  To the spindle in constant surface speed control, th e thread/ thread cycle or th e tapping cycle/ synchro- nous tapping cycle are commanded from other part system. Remedy  Check the program.

Source: Mitsubishi M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

Mitsubishi M800/M80 CNC のアラームについて

Mitsubishi によって構築された産業用コントローラーは、内部回路と機械的リンケージを保護するための広範な診断システムで設計されています。M800/M80 CNC が M01-1105 のようなエラーコードをスローする場合、通常、指令値と実際のセンサーフィードバック間の不一致を示します。

完全アラーム一覧: 722 Mitsubishi M800/M80 CNC コードs.

Have a better solution?

Help the industrial community by sharing your repair experience for code M01-1105.

Manual conversion service

Need a searchable reference for more Mitsubishi M800/M80 CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

関連する Mitsubishi M800/M80 CNC コード