代码 M01-1105: Spindle speed fluctuation
问题描述与安全警告
Mitsubishi M800/M80 CNC 触发了严重的 Spindle speed fluctuation 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Details The actual spindle speed has fluctuated exceeding the allowable range, while spindle speed fluctuation detec- tion (G162) is active. The number following "S", which is output together with this alarm, indicates the spindle where speed fluctua- tions were detected. Remedy Unnecessarily large load may be applied to the spindle during automatic operation. Reduce the spindle load. To prevent this alarm from being output during sp indle speed fluctuation detec tion (G162), set the param- eter #1242 set14 BIT2 to ON. Sp synchro phase calc illegal 1106 Details Spindle synchronization phase alignment command was issued while the "phase shift calculation request" sig- nal was ON. Remedy Correct the program. Correct the sequence program. Illegal cmd in SP oscillation 1108 Details A function that cannot be used with spindle osc illation was commanded during spindle oscillation. Remedy Command the function after finishing spindle oscillation. SP oscillation cmd illegal 1109 Details Spindle oscillation was commanded during executing a f unction that cannot be used with spindle oscillation. Remedy Command spindle oscillation after finishing the func tion that cannot used with spindle oscillation. SP oscillation set val illegal 1110 Details Spindle oscillation was commanded while a value out of rang e is set as spindle oscillation amplitude or spindle oscillation frequency. Remedy Check the setting values of the amplitude and frequency. Sub part system I call error 1111 Details Sub part system control I command (G122) has been given to a part system where the sub part system I operation mode is deactivated. Sub part system control I command (G 122) has been given to a part system which is not reserved as the sub part system in M80. Remedy Activate the sub part system I operation mode for the sub part system before issuing G122. Part systems marked "SUB" on the monitor screen are under the sub partsys tem I operation mode. Command the sub part system start to the sub part system which is reserved with "#1483 SBS1_sys num" for M80. Sub part system II start error 1112 Details When the sub part system control II has been commanded, no part system is left capable of being activated as a sub part system. Remedy Do not exceed the maximum number of simultane ously activatable sub part systems when commanding G144. Set the parameter #1437 SBS2_Spec BI T0 to 0 if you wish to wait unt il the sub part system becomes ca- pable of being activated. Constant surface speed rdndnt 1113 Details Constant surface speed is commanded from other part syst em to the spindle that is in the thread/ thread cycle or the tapping cycle/ synchronous tapping cycle. To the spindle in constant surface speed control, th e thread/ thread cycle or th e tapping cycle/ synchro- nous tapping cycle are commanded from other part system. Remedy Check the program.
Source: Mitsubishi M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Mitsubishi M800/M80 CNC 警报
由 Mitsubishi 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 M800/M80 CNC 出现类似 M01-1105 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 722 Mitsubishi M800/M80 CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code M01-1105.
Need a searchable reference for more Mitsubishi M800/M80 CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026