代码 F00064: Drive attempted to do an automatic clone during startup.
问题描述与安全警告
Siemens SINAMICS G120 CU240S Drive 触发了严重的 Drive attempted to do an automatic clone during startup. 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Reaction: OFF 2 Acknowledge: Quit fault eg. via DI2 Cause: No Clone00.bin File in the correct directory /USER/SINAMICS/DATA. Remedy: If a automatic clone is required: - Insert MMC with correct File anc power cycle. If no automatic clone is required: - Remove MMC if not needed and power cycle. - Reset P8458 = 0 and power cycle.
Source: SINAMICS G120 Control Units CU240S Faults and Alarms (Edition 05/2007)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Siemens SINAMICS G120 CU240S Drive 警报
由 Siemens 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 SINAMICS G120 CU240S Drive 出现类似 F00064 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。