代码 F00395: Acceptance Test / Confirmation pending
问题描述与安全警告
Siemens SINAMICS G120 CU240S Drive 触发了严重的 Acceptance Test / Confirmation pending 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Reaction: OFF 2 Acknowledge: Quit fault eg. via DI2 Cause: This fault occurs after a Powermodul (PM) / Control Unit (CU) Swap or a Startup Clone. It can also be caused by a faulty read from the EEPROM, see F0051 for more details. The parameterset after a CU swap or a startup clone could have changed and might not match the application. This parameterset needs to be checked before the drive can start a motor. - r0949 = 3 / 4: Swap of PM/CU - r0949 = 5: Startup Clone via MMC has been performed - r0949 = 10: Before the last power up an acceptance test was pending due to a swap or a startup clone. Remedy: Safety Units: An Acceptance Test needs to be performed. Follow the the steps of the Acceptance Log which is part of the Oper- ating Instructions. After performing the acceptance test the fault can be acknowledged by the following procedure: P0010 = 30 P9761 = Safety password P7844 = 0 The fault will be cleared automatically and P0010 will be set back to 0 Non Safety Units: The current parameterset needs to be checked and confirmed by clearing the fault or setting P7844 = 0.
Source: SINAMICS G120 Control Units CU240S Faults and Alarms (Edition 05/2007)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Siemens SINAMICS G120 CU240S Drive 警报
由 Siemens 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 SINAMICS G120 CU240S Drive 出现类似 F00395 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code F00395.
Need a searchable reference for more Siemens SINAMICS G120 CU240S Drive manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026