代码 F00453: Motor Stalled
问题描述与安全警告
Siemens SINAMICS G120 CU240S Drive 触发了严重的 Motor Stalled 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Reaction: OFF 2 Acknowledge: Quit fault eg. via DI2 Cause: - In SLVC or VC (p1300 greater than 20) and Ramp rate too fast - In SLVC or VC (p1300 greater than 20) and done OFF2 and RUN onto a spinning motor without Flying start enabled - In SLVC (p1300 = 20 or 21) and load too large at very low frequency - In SLVC or VC (p1300 greater than 20) and no motor connected or motor too small for inverter - In VC, the motor cable phase sequence (U-V-W) and the encoder cable wiring may be wired up incorrectly. - The speed controller settings are not optimised to the application. This can cause instabilities. Remedy: - Reduce ramp rate in p1120 - Enable flying start (p1200 equal to 1) - Increase boost in p1611 - Connect motor or use larger motor for this inverter or use VF mode (p1300 less than 20). - Correct the wiring to the motor and / or the encoder as required. Confirm the rotation direction in V/f control mode and compare parameters r0061 and r0021. - Optimise the speed controller settings (gain and integration time).
Source: SINAMICS G120 Control Units CU240S Faults and Alarms (Edition 05/2007)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Siemens SINAMICS G120 CU240S Drive 警报
由 Siemens 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 SINAMICS G120 CU240S Drive 出现类似 F00453 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code F00453.
Need a searchable reference for more Siemens SINAMICS G120 CU240S Drive manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.