代码 120404: Setting up acyclic link %1 failed.%nSwitch off/on control, drives and HMI.
问题描述与安全警告
Siemens SINUMERIK 840D CNC 触发了严重的 Setting up acyclic link %1 failed.%nSwitch off/on control, drives and HMI. 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Parameters: %1 = Name of connection Definitions: Setting up an acyclic link with a drive unit for file transfer fr om/to this drive unit has failed. The file could not be transfe rred from/to this drive unit. The affected drive unit has the bus number and slave address specified in the link name: /DRIVE_<Bus number>_<Slave address>. Reaction: Alarm display. Remedy: Execute the following meas ures in the sequence specified until t he process leading to the alarm can be repeated successfully: 1. Switch off/on control, drives and HMI, and then repeat the process leading to the alarm. 2. Load PROFIBUS configuration (HW Config) with same PLC and CP-Subnet-ID in PLC and CP, switch off/on control and HMI, and then repeat the process leading to the alarm. 3. Return to factory settings of the affected driv e unit, switch off/on control, drives and HMI, and then repeat the process leading to the alarm. 4. Contact Siemens AG, Industry Sector, I DT MC, Hotline (Phone/Fax: see Alarm 1000) regarding the error text. Program Continuation: Internal
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Siemens SINUMERIK 840D CNC 警报
由 Siemens 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 SINUMERIK 840D CNC 出现类似 120404 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 4014 Siemens SINUMERIK 840D CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 120404.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026