代码 206050: <location>Infeed: Smart Mode not supported

问题描述与安全警告

Siemens SINUMERIK 840D CNC 触发了严重的 <location>Infeed: Smart Mode not supported 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。

官方故障排除步骤

Message value: Drive object: A_INF, S_INF Reaction: OFF2 Acknowledge: IMMEDIATELY (POWER ON) Cause: The power unit does not support the Smart Mode. Remedy: - set the suitable sampling time 250 µs <= p0115[0] <= 400 µs (e.g. by setting p0112 and p0115 to the factory setting). - upgrade the power unit software and/or hardware for the Smart Mode. The availability of the Smart Mode function is displayed in r0192. - for A_INF the following applies: De-activate th e Smart Mode with p3400.0 = 0 and activate the voltage control with p3400.3 = 1. For booksize power units, it must be noted that for a supply voltage p0210 > 415 V only the Smart Mode is possible in th e pre-setting. If DC link voltages above 660 V are permissible in the application, then voltage-cont rolled operation can be activated with p0280, p0210, p3400 and p3510. The information regarding p0210 should be carefully noted. See also: r0192 (Power unit firmware properties)

Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

关于 Siemens SINUMERIK 840D CNC 警报

由 Siemens 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 SINUMERIK 840D CNC 出现类似 206050 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。

完整报警清单: 4014 Siemens SINUMERIK 840D CNC 代码s.

Have a better solution?

Help the industrial community by sharing your repair experience for code 206050.

Manual conversion service

Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

相关的 Siemens SINUMERIK 840D CNC 代码