代码 207906: <location>Armature short-circui t / internal voltage protection: Parameterization error
问题描述与安全警告
Siemens SINUMERIK 840D CNC 触发了严重的 <location>Armature short-circui t / internal voltage protection: Parameterization error 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Message value: Fault cause: %1, motor data set: %2 Drive object: SERVO, VECTOR Reaction: OFF2 Acknowledge: IMMEDIATELY Cause: The armature short-circuit is incorrectly parameterized. Fault value (r0949, interpret decimal): Low word: Motor data set number High word: Cause: 1: A permanent-magnet synchronous motor has not been selected. 101: External armature short-circui t: Output (r1239.0) not connected up. 102: External armature short-circuit with c ontactor feedback signal: No feedback signal connected (BI:p1235). 103: External armature short-circuit withou t contactor feedback signal: Delay time when opening (p1237) is 0. 201: Internal voltage protection: The maximum output current of the Motor Module (r0289) is less than 1.8 * motor short-circuit current (r0331). 202: Internal voltage protection: A Motor Module in booksize format is not being used. 203: Internal voltage protection: The motor short-ci rcuit current (p0320) is greater than the maximum motor current (p0323). 204: Internal voltage protection: The activation (p1231 = 4) is not given for all motor data sets with synchronous motors (p0300 = 2xx, 4xx). SINAMICS-Alarms Remedy: Re cause 1: - an armature short-circuit / voltage protection is only permissible for permanent-magnetic synchronous motors. The highest position of the motor type in p0300 must either be 2 or 4. Re cause 101: - the contactor for the external armature short-ci rcuit configuration should be controlled using output signal r1239.0. The signal can, e.g. be connected to an output terminal BI: p0738. Before this fault can be acknowledged, p1231 must be set again. Re cause 102: - if the external armature short-circuit with cont actor feedback signal (p1231 = 1) is selected, this feedback signal must be connected to an input termin al (e.g. r722.x) and then connected to BI: p1235. - alternatively, the external armature short-circ uit without contactor feedback signal (p1231 = 2) can be selected. Re cause 103: - if the external armature short-circuit without contactor feedback signal (p1231 = 2) is selected, then a delay time must be parameterized in p1237. This time must always be greater than the actual contactor opening time, as otherwise the Motor Module would be short-circuited! Re cause 201: - a Motor Module with a higher maximum current or a motor with a lower short-circuit current must be used. The maximum Motor Module current must be higher than 1.8 * short-circuit current of the motor. Re cause 202: - for internal voltage protection, us e a Motor Module in booksize format. Re cause 203: - for internal voltage protection, onl y use short-circuit proof motors. Re cause 204: - The internal voltage protection must either be activated for all motor data sets with synchronous motors (p0300 = 2xx, 4xx) (p1231 = 3) or it must be de-activated for all motor data sets (p1231 not equal to 3). This therefore ensures that the protec tion cannot be accidentally wi thdrawn as a result of a data set changeover. The fault can only be acknowledged if this c ondition is fulfilled.
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Siemens SINUMERIK 840D CNC 警报
由 Siemens 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 SINUMERIK 840D CNC 出现类似 207906 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 4014 Siemens SINUMERIK 840D CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 207906.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.