Código 230027: <location>Power unit: Prec harging DC link time monitoring
Descripción del problema y advertencia de seguridad
El Siemens SINUMERIK 840D CNC ha desencadenado una alarma crítica <location>Power unit: Prec harging DC link time monitoring. Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.
Pasos oficiales de solución de problemas
Message value: Enable signals: %1, Status: %2 Drive object: All objects Reaction: OFF2 Acknowledge: IMMEDIATELY Cause: The power unit DC link was not able to be pre-charged within the expected time. 1) There is no line supply voltage connected. 2) The line contactor/line side switch has not been closed. 3) The line supply voltage is too low. 4) Line supply voltage incorrectly set (p0210). 5) The pre-charging resistors are overheated as t here were too many pre-charging operations per time unit. 6) The pre-charging resistors are overheated as the DC link capacitance is too high. 7) The pre-charging resistors are overheated because when there is no "ready for operation" (r0863.0) of the infeed unit, power is taken from the DC link. 8) The pre-charging resistors are overheated as the line contactor was closed during the DC link fast discharge through the Braking Module. 9) The DC link has either a ground fault or a short-circuit. 10) The pre-charging circ uit is possibly defective (only for chassis units). Fault value (r0949, interpret binary): Missing internal enable signals, power unit (lower 16 bit): (Inverted bit-coded representation FFFF hex -> all internal e nable signals available) Bit 0: Power supply of the IGBT gating shut down Bit 1: Reserved Bit 2: Reserved Bit 3: Ground fault detected Bit 4: Peak current intervention Bit 5: I2t exceeded Bit 6. Thermal model overtemperature calculated Bit 7: (heat sink, gating module, pow er unit) overtemperature measured Bit 8: Reserved Bit 9: Overvoltage detected Bit 10: Power unit has completed pr e-charging, ready for pulse enable Bit 11: STO terminal missing Bit 12: Overcurrent detected Bit 13: Armature s hort-circuit active Bit 14: DRIVE-CLiQ fault active Bit 15: Uce fault detected, transistor de-s aturated due to overcurrent/short-circuit Status, power unit (upper 16 bit, hexadecimal number): 0: Fault status (wait for OFF and fault acknowledgement) 1: Restart inhibit (wait for OFF) 2: Overvoltage condition detected -> change into the fault state 3: Undervoltage condition detected -> change into the fault state 4: Wait for bypass contactor to open -> change into the fault state 5: Wait for bypass contactor to open -> change into restart inhibit 6: Commissioning 7: Ready for pre-charging 8: Pre-charging started, DC link voltage lower than the minimum switch-on voltage 9: Pre-charging, DC link voltage end of pre-charging still not detected 10: Wait for the end of the de-bounce time of the main contactor after pre-charging has been completed 11: Pre-charging completed, ready for pulse enable 12: It was detected that the STO terminal was energized at the power unit See also: p0210 (Drive unit line supply voltage) SINAMICS-Alarms Diagnostics Manual (DAsl), 03/2009 Remedy: In general: - check the line supply voltage at the input terminals. - check the line supply voltage setting (p0210). - the following applies to booksize units: Wait (approx. 8 min.) until the pre-charging resistors have cooled down. For this purpose, preferably disc onnect the infeed unit from the line supply. Re 5): - carefully observe the permissibl e pre-charging frequency (refer to the appropriate Equipment Manual). Re 6): - check the total capacitance of the DC link and if required, correspondingly reduce the maximum permissible DC link capacitance (refer to the appropriate Equipment Manual). Re 7): - interconnect the ready for operation signal of the in feed unit (r0863.0) in the enable logic of the drives connected to this DC link. Re 8): - check the connections of the ex ternal line contactor. The line contactor must be open during the DC link fast discharge. Re 9): - check the DC link regarding ground fault or short-circuit. See also: p0210 (Drive unit line supply voltage)
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Acerca de las alarmas de Siemens SINUMERIK 840D CNC
Los controladores industriales construidos por Siemens están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un SINUMERIK 840D CNC arroja un código de error como 230027, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.
Lista completa de alarmas: 4014 Siemens SINUMERIK 840D CNC códigos.
Have a better solution?
Help the industrial community by sharing your repair experience for code 230027.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.