Código 232860: <location>Encoder 2 DRIVE-CLiQ (CU): Telegram error
Descripción del problema y advertencia de seguridad
El Siemens SINUMERIK 840D CNC ha desencadenado una alarma crítica <location>Encoder 2 DRIVE-CLiQ (CU): Telegram error. Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.
Pasos oficiales de solución de problemas
Message value: Component number: %1, fault cause: %2 Drive object: All objects Reaction: A_INFEED: NONE (OFF1, OFF2) SERVO: OFF1 (IASC/DCBRAKE, NONE, OFF2, OFF3) VECTOR: OFF1 (IASC/DCBRAKE, NONE, OFF2, OFF3) Acknowledge: IMMEDIATELY Cause: A DRIVE-CLiQ communication error has occurred from t he Sensor Module (encoder 2) involved to the Control Unit. Fault value (r0949, interpret hexadecimal): yyxx hex: yy = component number, xx = fault cause xx = 11 hex = 17 dec: CRC error and the receive telegram is too early. xx = 01 hex = 01 dec: Checksum error (CRC error). xx = 12 hex = 18 dec: The telegram is shorter than that specified in the l ength byte or in the receive list and the receive telegram is too early. xx = 02 hex = 02 dec: Telegram is shorter than specified in t he length byte or in the receive list. xx = 13 hex = 19 dec: The telegram is longer than that specified in the lengt h byte or in the receive list and the receive telegram is too early. xx = 03 hex = 03 dec: Telegram is longer than specified in t he length byte or in the receive list. SINAMICS-Alarms xx = 14 hex = 20 dec: The length of the receive telegram does not match the receive list and the receive telegram is too early. xx = 04 hex = 04 dec: The length of the receive telegram does not match the receive list. xx = 15 hex = 21 dec: The type of the receive telegram does not match the re ceive list and the receive telegram is too early. xx = 05 hex = 05 dec: The type of the receive telegram does not match the receive list. xx = 16 hex = 22 dec: The address of the power unit in the telegram and in the receive list does not match and the receive telegram is too early. xx = 06 hex = 06 dec: The address of the power unit in the telegram and in the receive list do not match. xx = 19 hex = 25 dec: The error bit in the receive telegram is set and the receive telegram is too early. xx = 09 hex = 09 dec: The error bit in the receive telegram is set. xx = 10 hex = 16 dec: The receive telegram is too early. Remedy: - carry out a POWER ON. - check the electrical cabinet design and cable routing for EMC compliance - check the DRIVE-CLiQ wiring (i nterrupted cable, contacts,...). See also: p9915 (DRIVE-CLiQ data transfer error shutdown threshold master)
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Acerca de las alarmas de Siemens SINUMERIK 840D CNC
Los controladores industriales construidos por Siemens están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un SINUMERIK 840D CNC arroja un código de error como 232860, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.
Lista completa de alarmas: 4014 Siemens SINUMERIK 840D CNC códigos.
Have a better solution?
Help the industrial community by sharing your repair experience for code 232860.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.