代码 4152: Illegal configuration of the 'Block display with absolute values' function
问题描述与安全警告
Siemens SINUMERIK 840D CNC 触发了严重的 Illegal configuration of the 'Block display with absolute values' function 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Definitions: The "Block display with absolute values " function has been ill egally parameterized: - An illegal block length has been set with MD28400 $MC_MM_ABSBLOCK: While ramping up, the machine data will be checked for the following value range: 0, 1, 128 to 512 - An invalid display range has been set with MD28402 $MC_MM_ABSBLOCK_BUFFER_CONF[]. While ramping up, the machine data will be chec ked for the following upper and lower limits: 0 <= MD28402 $MC_MM_ABSBLOCK_BUFFER_CONF[0] <= 8 0 <= MD28402 $MC_MM_ABSBLOCK_BUFFER_CONF[1] <= (MD28060 $MC_MM_IPO_BUFFER_SIZE + MD28070$MC_MM_NUM_BLOCKS_IN_PREP). Alarm 4152 is issued if the limits are violated. Reaction: Mode group not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Remedy: Configure block length/display ran ge within the permissible limits. Program Continuation: Switch control OFF - ON.
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Siemens SINUMERIK 840D CNC 警报
由 Siemens 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 SINUMERIK 840D CNC 出现类似 4152 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 4014 Siemens SINUMERIK 840D CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 4152.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026